Kern-sohn MWS 400K100DM Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Échelles Kern-sohn MWS 400K100DM. KERN & SOHN MWS 400K100DM User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 59
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-mail: info@kern-sohn.com
Tel.: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Website: www.kern-sohn.com
Operating Instructions
Personal weighing scale, Handrail scale, Bariatric scale,
Wheelchair scale, Transportation stretcher balance
KERN MPS_M / MTS_M / MXS_M / MWS_M
Version 1.7
03/2014
GB
MPS / MTS / MXS / MWS-BA-e-1417
Vue de la page 0
1 2 3 4 5 6 ... 58 59

Résumé du contenu

Page 1 - Operating Instructions

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-mail: [email protected] Tel.: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Website: www.kern-so

Page 2

The scale platform can only be walked on by people that can stand on it securely with both feet, or sit calmly (in the case of chair scale and wheel

Page 3

3.4 Guarantee The guarantee shall become void in the event of the following: • non-observation of our guidelines in the Operating Instructions, •

Page 4 - 1 Technical data

4 Basic safety directions 4.1 Observing the directions included in the Operating Instructions  Carefully read this operation manual before set

Page 5

5 EMC guidance and manufacturer's declaration Guidance and manufacturer’s declaration-electromagnetic emissions The MTS300K100M; MXS300K100M;

Page 6 - 2 Declaration of conformity

Guidance and manufacturer’s declaration-electromagnetic immunity The MTS300K100M; MXS300K100M; MPS200K100M; MPS200K100PM; MWS300K100M; MWS400K100DM,

Page 7 - Kern & Sohn GmbH

Guidance and manufacturer’s declaration-electromagnetic immunity The MTS300K100M; MXS300K100M; MPS200K100M; MPS200K100PM; MWS300K100M; MWS400K100DM,

Page 8

Recommended separation distance between portable and mobile RF communications equipment and the MTS300K100M; MXS300K100M; MPS200K100M; MPS200K100PM;

Page 9

6 Transport and storage 6.1 Check upon delivery Please check the packaging immediately upon delivery and the device during un-packing for any visib

Page 10

7 Unpacking, installation and starting 7.1 Place of installation, place of use The scale is designed in such a way that reliable weighing results c

Page 11

7.3 Installation and setting of scale Personal weighing scale MPS with wall bracket: Scope of delivery: MPS / MTS / MXS / MWS-BA-e-1417 19

Page 12 - 4 Basic safety directions

GB KERN MPS 200K100M / PM KERN MTS 300K100M KERN MXS 300K100M KERN MWS 300K100M KERN MWS 400K100DM KERN MWS 300K1LM Version 1.7 03/2014 Operating

Page 13

Personal weighing scale MPS-PM with column: Scope of delivery: • Balance with display unit and tripod • Mains adapter • 4

Page 14

Assembly:  Remove cap (1)  Unscrew the screw (2)  Pull cable with Plug-in con-nection (3) through the sup-porting foot (4) and pull it out a

Page 15

 Introduce cable completely into the tripod tube (6)  Reinsert cap (1)  Screw-in screw (2) When screwing the screw ensure that the plug-

Page 16

 Adjust foot screw of the tripod in a way that the tripod has a safe base and is not loose. MPS / MTS / MXS / MWS-BA-e-1417 23

Page 17 - 6 Transport and storage

Mounting height measuring rod MSF 200: How to attach to KERN scale Use the 2 screws for screwing the bracket into the supplied insert nuts on the

Page 18

Scale MTS with handrail: Scope of delivery: MPS / MTS / MXS / MWS-BA-e-1417 25

Page 19

Assembly: Fasten 3 corner elements to the platform, using 4 screws each time. Place the handrail on 3 corner elements and screw it.

Page 20

Bariatric scale MXS: Scope of delivery: MPS / MTS / MXS / MWS-BA-e-1417 27

Page 21

Wheelchair scale MWS: Scope of delivery: MPS / MTS / MXS / MWS-BA-e-1417 28

Page 22

Direction concerning installation of external column on MPS model without column, MXS and MWS models  Fasten the round plate to the aluminium prof

Page 23

7.5 Battery operation/ Rechargeable battery operation (optional) ...36 7.5.1 Battery operation ...

Page 24

Assembly of holding bracket set MWS-A02 at the MWS models 1 Railing 6 Screw 2 Handrail butts 7 Hexagonal socket wrench 3 Cross strut 8 Scre

Page 25

We recommend engaging a second person to assist you during installa-tion. Carefully remove the plastic cover from the weighing scale, ensuring

Page 26

Ensuring perfect fit, put the handrail con-taining three holes for the display unit on the handrail butt (1) and cable conduit. (see fig.) Using

Page 27

Take a screw driver and remove the plastic covers from both sides of the dis-play unit. Screw the display unit to the handle, us-ing the synthetic

Page 28

Using the synthetic covers, seal both holes in the two handrail butts without cross struts. Once installation is complete, check all screws for

Page 29

7.3.1 Scope of delivery Standard accessories: • Mains adapter (complaint with EN 60601-1 standard). • Operating Instructions 7.3.2 Installat

Page 30

7.4 Mains socket Power supply is carried out by means of the external mains adapter which also pro-vides separation between mains and a scale. The

Page 31

7.5.1 Battery operation On models where the back of the display unit is not directly accessible, remove the two black rotary knobs from both sides

Page 32

 Insert battery holder with the inserted batteries into the display unit Ensure that the cables are not squeezed  Close the battery cover I

Page 33

7.5.2 Rechargeable battery operation (optional) When an optional rechargeable battery is used, proceed as follows: On models where the back of the

Page 34

1 Technical data KERN MPS 200K100M/PM MTS 300K100M MXS 300K100M Display 6-position one Weighing range (max.) 200 kg 300 kg 300kg Minimal load (

Page 35

 Carefully insert the rechargeable bat-tery block and insert plug into connec-tion CN 3 Ensure that the cables are not squeezed  Close the bat

Page 36

7.6 Initial start-up To obtain accurate weighing results with electronic scales, the appropriate operating temperature is to be provided for them (re

Page 37

8 Operation 8.1 Operation elements - 20 keys of the terminal 8.1.1 Display 8.1.2 Display view No. Display Description 1 [→0←] Scale zero dis

Page 38

6 PRE-TARE  Initially set tare value is active. 7 NET  The net weight is displayed. 8 WEIGHT  The present weight value is displayed. 8.1.3

Page 39

9 Using scale 9.1 Weighing  Switch on the scale with the [ON/OFF] key. The diagnostic scale self-check is performed and then the software version

Page 40

9.2 Taring The dead weight of any initial load used for weighing may be tared away by pressing the key, so that the following weighing shows the rea

Page 41

9.4 Mother/Child Function The “Mother/Child” function makes it possible to determine the body weight of infants and small children held in an adult’

Page 42 - 8 Operation

9.5.1 Classification of BMI values Classification of weight for adults over 18 years on the basis of Body Mass Index according to WHO, 2000 EK IV a

Page 43

9.6.1 PRE-TARE function with 5 memories Owing to this function it is possible to store 5 Pre-Tare values (e.g. for different wheelchairs), and then

Page 44 - 9 Using scale

Printing Pre-Tare memory (refer also to section 8.6): To do this, press the PRE-Tare key repeatedly until the display will show the „ni” (M) symbol.

Page 45

KERN MWS 300K1LM MWS 300K100M MWS 400K100DM Display 6-position one Weighing range (max.) 300 kg 300 kg 300kg; 400kg Minimal load (min.) 2 kg 2

Page 46

10 Error messages The following messages can be shown on the display during switching on or using the scale. ERRL: Too small weight on the scale. o

Page 47

11.2 Service, maintenance The device may only be operated and maintained by trained service technicians who are authorised by KERN. Disconnect the s

Page 48

12 Troubleshooting The scale should be switched off for a short time following an interruption in the pro-gram sequence and disconnected from mains

Page 49

13 Verification If a scale is verified, then a verification office or manufacturer puts a verification mark and one or several seals (seals are damage

Page 50 - 10 Error messages

Press the [TARE] key, the display will show the present numerical value. Then press the [ENTER] key. 30770  CAL O �� Press the [HOLD] key. CAL 5 �

Page 51

13.2 Adjustment key and seals When verification of a scale is finished, the positions indicated on the scale are sealed. Verification of a scale wi

Page 52 - 12 Troubleshooting

3. MPS 4. MXS, MTS 5. MWS MPS / MTS / MXS / MWS-BA-e-1417 56

Page 53 - CAL U ��

Position of adjustment switch: Position of adjustment switch Status 1. left side not documented 2. centre adjustment position - adjustment i

Page 54 - CAL 5 ��

Navigation in menu:  When the scale is switched on, press and hold the [→0←] key pressed for about 3 seconds until the display shows successively

Page 55

Description: Weight unit: kg Scale divisions, weighing range (max.) and read-out (d) Selection of multi-range / single-range scale Single-ra

Page 56

2 Declaration of conformity Declaration of conformity: refer to the separate document with serial number of the device CE marking: 029

Page 57

Please note operating instructions Please note operating instructions Marking of the medical device manufacturer wi

Page 58

3 Basic directions (general information) According to the Directive 2009/23/EC scales must be verified to the fol-lowing application purposes. Arti

Page 59

3.2 Intended use Depending on the model, the scale is used to determine the weight of standing per-sons, sitting persons and persons lying on a tran

Commentaires sur ces manuels

Pas de commentaire